Health Violations Found NM 3 HEALTH VIOLATIONS

La Jara Water Users Association

EPA ID: NM3509223 · 458 people served · 1 ZIP code

La Jara Water Users Association carries 1 open EPA violation that remain unresolved in the federal system — approximately 458 people fall within its service area.

Data: EPA SDWIS Last verified: 2026-04-02

B · 76
Avg Safety Score
458
People Served
1
ZIP Code Served
5
Violations (5yr)
Surface Water
Water Source
0.0023 mg/L
Max Lead Level
Zone 2
Radon Risk · Moderate
4
Contaminants Flagged

Compliance Trajectory

Stable · Risk tier: High · 91% chance of violation in next 12 months

Violations went from 1 (2023) to 1 (2024). Violation counts have remained relatively steady.

Service Area Map

Coverage area for La Jara Water Users Association Source: EPA SDWIS service area boundaries.

Service area boundary — Grade B

🌊 Where Does Your Water Come From?

Surface Water

La Jara Water Users Association's water is drawn from rivers, lakes, or reservoirs. Surface water sources are more exposed to agricultural runoff, stormwater, and upstream discharges, but they typically receive more intensive treatment before reaching your tap.

Elevated Risk
Source Contamination Risk
70th
Wastewater Discharge Proximity
40th
Superfund Site Proximity

About 2% of homes in Sandoval County, New Mexico rely on private wells rather than public water systems. Private well owners are responsible for their own water testing and treatment.

Wastewater Proximity Note: This service area ranks in the 70th percentile nationally for proximity to wastewater discharge points. Surface water sources near wastewater outfalls may face additional treatment challenges.

Infrastructure Risk

38 yr
Avg Pipe Age
Copper
Pipe Material
32 yr
Est. Remaining Life
Stable
Decay Status
Installed 54% of expected lifespan used End of life

Detected Contaminants

How La Jara Water Users Association compares to EPA limits

Haloacetic Acids (HAA5) 1 mg/L (EXCEEDS LIMIT)
0 EPA Limit: 0.06 mg/L
Cancer risk; reproductive & developmental effects
Total Trihalomethanes (TTHM) 1 mg/L (EXCEEDS LIMIT)
0 EPA Limit: 0.08 mg/L
Bladder & rectal cancer risk; reproductive concerns

What This Means For You

Haloacetic Acids (HAA5) at 1 mg/L exceeds the EPA maximum of 0.06 mg/L. Cancer risk; reproductive & developmental effects. Consider granular activated carbon (GAC) filtration.

Total Trihalomethanes (TTHM) at 1 mg/L exceeds the EPA maximum of 0.08 mg/L. Bladder & rectal cancer risk; reproductive concerns. Consider granular activated carbon (GAC) filtration.

Stage 2 DBP Rule at 2 mg/L exceeds the EPA maximum of mg/L.

Lead and Copper Rule at 1 mg/L exceeds the EPA maximum of mg/L.

Haloacetic Acids (HAA5) was detected in this water system. granular activated carbon (GAC) filtration can reduce exposure.

Find a certified water filter →

Comparable Water Systems

Similar-sized systems in New Mexico

Apple Orchard Mdwca
460 people
0 violations
0 violations
0 violations
Valley Mdwca
454 people
0 violations
Eileen Acres
462 people
0 violations

Estimated Remediation Costs

Average estimated costs across ZIP codes served by this system

Water Filtration Radon Mitigation
Water Filtration $600
Radon Mitigation $400
Total Estimated Cost $1,000

Based on national averages for common remediation projects. Actual costs vary by property. Only issues flagged by EPA, FEMA, or state data for each ZIP code are included.

Cost of Inaction

If water quality issues in this service area are not addressed, the estimated financial impact per household is:

Estimated Healthcare Costs $1,000

Annual per household (CDC est.)

Estimated Cumulative Cost Per Household

5 years
$5,000
10 years
$10,000
20 years
$20,000

Compare: Estimated remediation cost is $1,000 (one-time) vs. $10,000 in estimated inaction costs over 10 years.

Estimates based on published EPA, CDC, and peer-reviewed research. Individual costs vary by household size, property, and health factors. These are conservative lower-bound estimates intended for awareness, not financial advice.

System Overview

La Jara Water Users Association (EPA ID: NM3509223) is a community water system in New Mexico that serves approximately 458 people from surface water sources.

This system serves ZIP code 87027 in La Jara.

Average Home Safety Score: B (76/100)

Based on water quality violations, lead levels, and radon risk across all ZIP codes served by this system.

Violation History

3 health-based violations recorded in the past 5 years. 1 remains unresolved.

Recent Violations

Date Contaminant Type Status
October 17, 2024 Stage 2 DBP Rule Monitoring Resolved
October 17, 2024 Stage 2 DBP Rule Health-based Resolved
July 1, 2023 Haloacetic Acids (HAA5) Health-based Unresolved

Contaminants Detected

The following contaminants have been flagged in EPA records for this water system:

Contaminant Category Violations Health-Based
Stage 2 DBP Rule Treatment Failure 2 Yes
Total Trihalomethanes (TTHM) Disinfection Byproducts 1 Yes
Haloacetic Acids (HAA5) Disinfection Byproducts 1 Yes
Lead and Copper Rule Treatment Failure 1 No

Health Risk Details

Total Trihalomethanes (TTHM) (EPA limit: 0.08 mg/L)

Bladder & rectal cancer risk; reproductive concerns At-risk groups: pregnant women, long-term consumers of chlorinated water, people who frequently shower in chlorinated water.

Removal methods: granular activated carbon (GAC), carbon block filter, point-of-entry aeration. Find the right filter →

Haloacetic Acids (HAA5) (EPA limit: 0.06 mg/L)

Cancer risk; reproductive & developmental effects At-risk groups: pregnant women, infants, long-term consumers of chlorinated municipal water.

Removal methods: granular activated carbon (GAC), carbon block filter, reverse osmosis. Find the right filter →

Lead & Copper

EPA Lead and Copper Rule sampling data for ZIP codes served by this system:

ZIP Code Lead Level Exceeds Limit Sample Date
87027 0.0023 mg/L No N/A

Radon Risk in Service Area

Dominant radon zone for ZIP codes served by this system: Zone 2 (Moderate Risk)

The EPA recommends testing homes in Zone 1 and Zone 2 areas for radon.

Need help with your water quality?

Typical cost: Water test: typically $20–$50 (DIY kit) · Professional inspection: $150–$400

Find the Right Water Filter

Free tip: Let cold water run for 2 minutes before drinking — this helps flush lead from your pipes.

ZIP Codes Served

Data Sources

This report uses public data from the EPA Safe Drinking Water Information System (SDWIS). View the full compliance record for La Jara Water Users Association (NM3509223) on EPA.gov.

Frequently Asked Questions

Is La Jara Water Users Association water safe to drink?

La Jara Water Users Association has recorded 3 health-based violations in the past 5 years. While the system is required to treat water to meet federal standards, you may want to consider additional precautions such as a certified water filter.

How many people does La Jara Water Users Association serve?

La Jara Water Users Association serves approximately 458 people across 1 ZIP code in New Mexico.

Where does La Jara Water Users Association get its water?

The primary water source is surface water.

Water Source & Treatment

Where this water originates and how it's treated before reaching your tap.

Source
Surface water
Drawn from rivers, lakes, or reservoirs.
Disinfectant used
Chlorine
Treatment chemicals reported
chlorine

Source: LA JARA WATER USERS ASSOCIATION Consumer Confidence Report.

ZipCheckup is not affiliated with this water utility. Treatment and source data are sourced from the utility's published CCR filings.

Treatment regime

How this utility classifies its treatment process and what each reported treatment chemical does.

Treatment classification
Standard
Disinfection plus one or more treatment additives — typically corrosion control, pH adjustment, or fluoridation. Standard regime for utilities serving treated municipal water.

Treatment chemicals and what each one does

Chemical names are reported verbatim by the utility. Purpose categories are ZipCheckup annotations based on standard drinking-water treatment practice.

Disinfectant
Inactivates bacteria, viruses, and parasites in the treated water.
chlorine

Treatment classification and chemical list sourced from LA JARA WATER USERS ASSOCIATION Consumer Confidence Report.

Treatment intensity is a ZipCheckup-derived classification based on the chemicals and processes the utility reports. Chemicals and contamination sources are taken verbatim from the utility's CCR filing. Routine federal monitoring and contaminant testing shown elsewhere on this page determine whether the water meets safety standards, not the treatment classification.

Lead Service Line Inventory

Service line breakdown reported under the federal Lead and Copper Rule Improvements (LCRI) inventory requirement:

1
Confirmed Lead
0
Galvanized — Replacement Required
72
Unknown Material
120
Confirmed Non-Lead

Federal LCRI rule (effective October 2024) requires every public water system to inventory its service lines and complete lead-line replacement within 10 years.

Federal Regulatory Status · 2026Q1
LCRR inventory submission: Reported all required service line types
Latest tap sample on 2023-01-01 did not exceed the federal lead action level.
Reporting compliance issue flagged by EPA under Rule 2E.
Compliance issue flagged by EPA under Rule 4G.
Population served: 458
Reported to New Mexico

Source: EPA SDWIS Federal Service Line Inventory (Phase 2) · Submitted 2026

ZipCheckup is not affiliated with the utility or state agency. Inventory figures render verbatim from the public LCRI submission cited above; ZipCheckup does not perform inspections or replacements.

Learn about lead in drinking water →

Notable events and violations

This section summarizes events the utility chose to disclose in its most recent Consumer Confidence Report, plus any federal compliance violations the utility recorded against itself. Both lists are utility-authored — ZipCheckup does not audit, judge, or reorder them.

Federal compliance violations on record

These entries are taken verbatim from the utility's CCR violations section. EPA defines four broad violation categories: Maximum Contaminant Level (MCL), Treatment Technique (TT), Monitoring & Reporting (M&R), and Public Notification (PN).

  • MCL · Haloacetic Acids (HAA5)
    2024
    MCL for Haloacetic Acids exceeded.
  • MCL · Total Trihalomethanes (TTHM)
    2024
    MCL for Total Trihalomethanes exceeded.

Violations record from LA JARA WATER USERS ASSOCIATION Consumer Confidence Report.

ZipCheckup note: items above reflect what the utility published in its most recent CCR. Federal violation records are also tracked separately by the EPA Safe Drinking Water Information System (SDWIS) — the SDWIS record is the authoritative federal source for any specific regulatory action.

Frequently Asked Questions

Is water from La Jara Water Users Association safe to drink?
La Jara Water Users Association earns a B safety grade with 5 violations in the past 5 years. Tap water meets EPA standards for most contaminants.
What contaminants are in La Jara Water Users Association's water?
Detected contaminants include Haloacetic Acids (HAA5), Total Trihalomethanes (TTHM), Stage 2 DBP Rule, Lead and Copper Rule. Each is compared against EPA maximum contaminant levels (MCLs) in the detailed breakdown above.
Should I use a water filter?
Given 4 contaminants above EPA limits, a certified water filter can provide an extra layer of protection. The best type depends on specific contaminants in your water.
How many people does La Jara Water Users Association serve?
La Jara Water Users Association serves approximately 458 people with drinking water across 1 ZIP code.
What is La Jara Water Users Association's water source?
La Jara Water Users Association draws water from surface water sources. Source type affects which contaminants are most likely to be present.
Is there lead in La Jara Water Users Association's water?
The maximum detected lead level is 0.0023 mg/L. This is within EPA action level guidelines.
Where does La Jara Water Users Association get its water?
La Jara Water Users Association's water is drawn from rivers, lakes, or reservoirs. Surface water sources are more exposed to agricultural runoff, stormwater, and upstream discharges, but they typically receive more intensive treatment before reaching your tap. Based on violation history and environmental factors, the source contamination risk is currently elevated.

What You Can Do

1

Test your water

Home test kits can detect lead, bacteria, and other contaminants at your tap. Find the right filter →

2

Check your specific ZIP code

Water quality can vary within a system. View nearest ZIP report →

3

Contact your utility

La Jara Water Users Association (EPA ID: NM3509223) — request the latest Consumer Confidence Report or ask about specific contaminants.

Home Water Systems New Mexico La Jara Water Users Association

Get safety alerts for La Jara Water Users Association, New Mexico

Free updates when EPA data changes for this area. No spam.

Unsubscribe anytime. Privacy Policy.

Share This Page

X Facebook
Violations found — check filter options Free tool — no phone call required.