D · 40
Avg Safety Score
1,100
People Served
3
ZIP Codes Served
6
Violations (5yr)
Groundwater
Water Source
0.12821 mg/L
Max Lead Level — Exceeds Limit
Zone 1
Radon Risk · High
5
Contaminants Flagged
$208K
Median Home Value in Service Area

Service Area Map

Coverage area for Chicora Boro Water Supply Source: EPA SDWIS service area boundaries.

Service area boundary — Grade D

Service Area Demographics

$82,676
Median Household Income
22,383
Service Area Population
9%
Disadvantaged Population
30th
Poverty Percentile
50th
Energy Burden Percentile
65%
Pre-1986 Housing

The Chicora Boro Water Supply serves a community with a median household income of $82,676 and an estimated 22,383 residents across its service area. Approximately 65% of housing stock was built before 1986, which increases the likelihood of lead service lines and older plumbing.

💧 Where Does Your Water Come From?

Groundwater

Chicora Boro Water Supply's water is pumped from underground aquifers. Groundwater is naturally filtered through rock and soil, but it can be vulnerable to PFAS contamination, nitrates from agriculture, and industrial chemicals that seep into the water table.

Elevated Risk
Source Contamination Risk
40th
Wastewater Discharge Proximity
40th
Superfund Site Proximity

About 1% of homes in Butler County, Pennsylvania rely on private wells rather than public water systems. Private well owners are responsible for their own water testing and treatment.

Infrastructure Risk

46 yr
Avg Pipe Age
Copper
Pipe Material
24 yr
Est. Remaining Life
Moderate Wear
Decay Status
Installed 66% of expected lifespan used End of life

Detected Contaminants

How Chicora Boro Water Supply compares to EPA limits

Haloacetic Acids (HAA5) 1 mg/L (EXCEEDS LIMIT)
0 EPA Limit: 0.06 mg/L
Cancer risk; reproductive & developmental effects
Copper 1 mg/L (77% of limit)
0 EPA Limit: 1.3 mg/L

What This Means For You

Haloacetic Acids (HAA5) at 1 mg/L exceeds the EPA maximum of 0.06 mg/L. Cancer risk; reproductive & developmental effects. Consider granular activated carbon (GAC) filtration.

Lead and Copper Rule at 2 mg/L exceeds the EPA maximum of mg/L.

Contaminant 2306 at 1 mg/L exceeds the EPA maximum of mg/L.

Contaminant 0700 at 1 mg/L exceeds the EPA maximum of mg/L.

Haloacetic Acids (HAA5) was detected in this water system. granular activated carbon (GAC) filtration can reduce exposure.

Find a certified water filter →

Comparable Water Systems

Similar-sized systems in Pennsylvania

C 4 violations
Sandy Lake Boro
1,100 people
B 3 violations
F 10 violations
D 3 violations
The Escape
1,100 people
C 26 violations

Estimated Remediation Costs

Average estimated costs across ZIP codes served by this system

Lead Pipe Replacement Radon Mitigation Flood Insurance Water Filtration
Lead Pipe Replacement $2,840
Radon Mitigation $1,200
Flood Insurance $800
Water Filtration $100
Total Estimated Cost $4,940

Based on national averages for common remediation projects. Actual costs vary by property. Only issues flagged by EPA, FEMA, or state data for each ZIP code are included.

Cost of Inaction

If water quality issues in this service area are not addressed, the estimated financial impact per household is:

Estimated Healthcare Costs $1,000

Annual per household (CDC est.)

Lead Exposure — Child Lifetime Cost $10,000

Per affected child (EPA est.)

Estimated Cumulative Cost Per Household

5 years
$7,780
10 years
$15,560
20 years
$31,120

Compare: Estimated remediation cost is $4,940 (one-time) vs. $15,560 in estimated inaction costs over 10 years.

Estimates based on published EPA, CDC, and peer-reviewed research. Individual costs vary by household size, property, and health factors. These are conservative lower-bound estimates intended for awareness, not financial advice.

System Overview

Chicora Boro Water Supply (EPA ID: PA5100029) is a community water system in Pennsylvania that serves approximately 1,100 people from groundwater sources.

This system provides water to 3 ZIP codes across 3 communities.

Average Home Safety Score: D (40/100)

Based on water quality violations, lead levels, and radon risk across all ZIP codes served by this system.

Violation History

1 health-based violation recorded in the past 5 years. 1 remains unresolved.

Recent Violations

Date Contaminant Type Status
July 1, 2025 Haloacetic Acids (HAA5) Monitoring Unresolved
June 13, 2025 Lead and Copper Rule Monitoring Resolved
June 1, 2025 Contaminant 0700 Health-based Resolved

Contaminants Detected

The following contaminants have been flagged in EPA records for this water system:

Contaminant Category Violations Health-Based
Lead and Copper Rule Treatment Failure 2 No
Copper Inorganic 1 No
Contaminant 2306 Other Violation 1 No
Haloacetic Acids (HAA5) Disinfection Byproducts 1 No
Contaminant 0700 Other Violation 1 Yes

Lead & Copper

EPA Lead and Copper Rule sampling data for ZIP codes served by this system:

ZIP Code Lead Level Exceeds Limit Sample Date
16025 0.12821 mg/L Yes N/A
Lead exceeds EPA action level in at least one sampling location. Consider using a certified NSF/ANSI 53 or NSF/ANSI 58 filter rated for lead removal.

Radon Risk in Service Area

Dominant radon zone for ZIP codes served by this system: Zone 1 (High Risk)

The EPA recommends testing homes in Zone 1 and Zone 2 areas for radon.

Need help with your water quality?

Typical cost: Water test: typically $20–$50 (DIY kit) · Professional inspection: $150–$400

Find the Right Water Filter

Free tip: Let cold water run for 2 minutes before drinking — this helps flush lead from your pipes.

ZIP Codes Served

Coverage: Service area ZIP codes sourced from EPA Community Water System Service Area Boundaries v3 (March 2026 release). These ZIPs reflect the actual deployment footprint recorded by PA or modeled from parcel and building-footprint data.

Data Sources

This report uses public data from the EPA Safe Drinking Water Information System (SDWIS). View the full compliance record for Chicora Boro Water Supply (PA5100029) on EPA.gov.

Frequently Asked Questions

Is Chicora Boro Water Supply water safe to drink?

Chicora Boro Water Supply has recorded 1 health-based violation in the past 5 years. While the system is required to treat water to meet federal standards, you may want to consider additional precautions such as a certified water filter.

How many people does Chicora Boro Water Supply serve?

Chicora Boro Water Supply serves approximately 1,100 people across 3 ZIP codes in Pennsylvania.

Where does Chicora Boro Water Supply get its water?

The primary water source is groundwater.

PFAS Substances Detected in This System

This water system's Consumer Confidence Report disclosed the following PFAS compounds. Levels are from the utility's most recent reporting cycle.

Substance Detected level EPA limit Status
PFHxS
Perfluorohexanesulfonic acid
EPA-regulated (2024 NPDWR)
0.671 ppt 10 ppt Below EPA limit
PFNA
Perfluorononanoic acid
EPA-regulated (2024 NPDWR)
0.389 ppt 10 ppt Below EPA limit
PFOS
Perfluorooctanesulfonic acid
EPA-regulated (2024 NPDWR)
2.32 ppt 4 ppt Below EPA limit
PFOA
Perfluorooctanoic acid
EPA-regulated (2024 NPDWR)
2.72 ppt 4 ppt Below EPA limit

In April 2024, EPA finalized the first National Primary Drinking Water Regulation for six PFAS. Public water systems have until 2029 to comply. EPA — PFAS regulation overview →

Source: Consumer Confidence Report disclosed by Chicora Boro Water Supply.

ZipCheckup is not affiliated with this water utility. PFAS detection data is sourced from public Consumer Confidence Reports filed by the utility itself.

Learn more about PFAS health effects and filtration →

Lead Service Line Inventory

Service line breakdown reported under the federal Lead and Copper Rule Improvements (LCRI) inventory requirement:

0
Confirmed Lead
0
Galvanized — Replacement Required
231
Unknown Material
173
Confirmed Non-Lead

This system reports zero confirmed lead service lines in its inventory. Unknown-material counts may still warrant verification.

Federal LCRI rule (effective October 2024) requires every public water system to inventory its service lines and complete lead-line replacement within 10 years.

Federal Regulatory Status · 2026Q1
LCRR inventory submission: Reported all required service line types
Latest tap sample on 1995-07-01 did not exceed the federal lead action level.
Population served: 1,100
Reported to Pennsylvania

Source: EPA SDWIS Federal Service Line Inventory (Phase 2) · Submitted 2026

ZipCheckup is not affiliated with the utility or state agency. Inventory figures render verbatim from the public LCRI submission cited above; ZipCheckup does not perform inspections or replacements.

Learn about lead in drinking water →

Frequently Asked Questions

Is water from Chicora Boro Water Supply safe to drink?
Chicora Boro Water Supply has a D safety grade based on 6 recorded violations. Some contaminants may exceed EPA limits — independent testing is recommended.
What contaminants are in Chicora Boro Water Supply's water?
Detected contaminants include Haloacetic Acids (HAA5), Lead and Copper Rule, Contaminant 2306, Contaminant 0700. Each is compared against EPA maximum contaminant levels (MCLs) in the detailed breakdown above.
Should I use a water filter?
Given 4 contaminants above EPA limits, a certified water filter can provide an extra layer of protection. The best type depends on specific contaminants in your water.
How many people does Chicora Boro Water Supply serve?
Chicora Boro Water Supply serves approximately 1,100 people with drinking water across 3 ZIP codes.
What is Chicora Boro Water Supply's water source?
Chicora Boro Water Supply draws water from groundwater sources. Source type affects which contaminants are most likely to be present.
Is there lead in Chicora Boro Water Supply's water?
The maximum detected lead level is 0.12821 mg/L. This exceeds the EPA action level of 0.015 mg/L. A lead-certified filter is recommended, especially for homes with young children.
What is the demographic profile of Chicora Boro Water Supply's service area?
The Chicora Boro Water Supply service area has a median household income of $82,676. Demographic data is sourced from the U.S. Census Bureau and EPA EJScreen.
Where does Chicora Boro Water Supply get its water?
Chicora Boro Water Supply's water is pumped from underground aquifers. Groundwater is naturally filtered through rock and soil, but it can be vulnerable to PFAS contamination, nitrates from agriculture, and industrial chemicals that seep into the water table. Based on violation history and environmental factors, the source contamination risk is currently elevated.

What You Can Do

1

Test your water

Home test kits can detect lead, bacteria, and other contaminants at your tap. Find the right filter →

2

Check your specific ZIP code

Water quality can vary within a system. View nearest ZIP report →

3

Contact your utility

Chicora Boro Water Supply (EPA ID: PA5100029) — request the latest Consumer Confidence Report or ask about specific contaminants.

Home Water Systems Pennsylvania Chicora Boro Water Supply

Get safety alerts for Chicora Boro Water Supply, Pennsylvania

Free updates when EPA data changes for this area. No spam.

Unsubscribe anytime. Privacy Policy.

Share This Page

X Facebook
Concerned about lead? Check your risk Free tool — no phone call required.