Doylestown Boro Water Department
EPA ID: PA1090081 · 8,700 people served · 5 ZIP codes
In the most recent EPA reporting cycle, Doylestown Boro Water Department carried 2 violations still marked as unresolved — each remains active in the federal enforcement ledger while the utility continues operations for its service population of approximately 8,700 people across the area it supplies.
Data: EPA SDWIS Last verified: 2026-04-02
Service Area Map
Coverage area for Doylestown Boro Water Department Source: EPA SDWIS service area boundaries.
Service area boundary — Grade D
Service Area Demographics
The Doylestown Boro Water Department serves a community with a median household income of $148,286 and an estimated 72,496 residents across its service area. Approximately 52% of housing stock was built before 1986, which increases the likelihood of lead service lines and older plumbing.
💧 Where Does Your Water Come From?
Doylestown Boro Water Department's water is pumped from underground aquifers. Groundwater is naturally filtered through rock and soil, but it can be vulnerable to PFAS contamination, nitrates from agriculture, and industrial chemicals that seep into the water table.
About 1% of homes in Bucks County, Pennsylvania rely on private wells rather than public water systems. Private well owners are responsible for their own water testing and treatment.
Wastewater Proximity Note: This service area ranks in the 60th percentile nationally for proximity to wastewater discharge points.
Superfund Proximity Note: This service area ranks in the 80th percentile nationally for proximity to Superfund (NPL) sites. Groundwater sources near contaminated sites may face elevated risk from industrial chemicals.
Infrastructure Risk
Detected Contaminants
How Doylestown Boro Water Department compares to EPA limits
What This Means For You
Atrazine at 1 mg/L exceeds the EPA maximum of 0.003 mg/L. Endocrine disruption, cardiovascular & reproductive effects. Consider granular activated carbon (GAC) filtration.
Consumer Confidence Report Rule at 4 mg/L exceeds the EPA maximum of mg/L.
Contaminant 0700 at 3 mg/L exceeds the EPA maximum of mg/L.
Revised Total Coliform Rule at 3 presence exceeds the EPA maximum of presence.
E. coli at 2 Zero tolerance (any positive sample triggers immediate action) exceeds the EPA maximum of Zero tolerance (any positive sample triggers immediate action). Severe GI illness; potentially fatal kidney failure in children. Consider UV disinfection (99.99%) filtration.
PFAS Detected in Service Area
PFAS ("forever chemicals") have been detected in water serving this system's area. 34 detections recorded. 9 exceed federal EPA limits (4 ppt for PFOA/PFOS). 8 exceed state limits.
Atrazine was detected in this water system. granular activated carbon (GAC) filtration can reduce exposure.
Find a certified water filter →Comparable Water Systems
Similar-sized systems in Pennsylvania
Estimated Remediation Costs
Average estimated costs across ZIP codes served by this system
Based on national averages for common remediation projects. Actual costs vary by property. Only issues flagged by EPA, FEMA, or state data for each ZIP code are included.
System Overview
Doylestown Boro Water Department (EPA ID: PA1090081) is a community water system in Pennsylvania that serves approximately 8,700 people from groundwater sources.
This system provides water to 5 ZIP codes across 4 communities.
Average Home Safety Score: D (49/100)
Based on water quality violations, lead levels, and radon risk across all ZIP codes served by this system.
Violation History
Recent Violations
| Date | Contaminant | Type | Status |
|---|---|---|---|
| January 1, 2024 | Atrazine | Monitoring | Resolved |
| December 1, 2023 | Contaminant 0700 | Monitoring | Unresolved |
| October 1, 2023 | Combined Radium | Monitoring | Unresolved |
| January 1, 2023 | Copper | Monitoring | Resolved |
| January 1, 2023 | Contaminant 2326 | Monitoring | Resolved |
Contaminants Detected
The following contaminants have been flagged in EPA records for this water system:
| Contaminant | Category | Violations | Health-Based |
|---|---|---|---|
| Consumer Confidence Report Rule | Reporting Failure | 4 | No |
| Contaminant 0700 | Other Violation | 3 | No |
| Revised Total Coliform Rule | Microbiological | 3 | No |
| E. coli | Microbiological | 2 | No |
| Copper | Inorganic | 1 | No |
| Atrazine | Organic | 1 | No |
| Contaminant 2326 | Other Violation | 1 | No |
| Combined Radium | Radionuclides | 1 | No |
| Stage 1 DBP Rule | Treatment Failure | 1 | No |
Lead & Copper
EPA Lead and Copper Rule sampling data for ZIP codes served by this system:
| ZIP Code | Lead Level | Exceeds Limit | Sample Date |
|---|---|---|---|
| 18901 | 0.0024 mg/L | No | N/A |
Radon Risk in Service Area
Dominant radon zone for ZIP codes served by this system: Zone 1 (High Risk)
The EPA recommends testing homes in Zone 1 and Zone 2 areas for radon.
Need help with your water quality?
Typical cost: Water test: typically $20–$50 (DIY kit) · Professional inspection: $150–$400
Find the Right Water FilterFree tip: Let cold water run for 2 minutes before drinking — this helps flush lead from your pipes.
ZIP Codes Served
Coverage: 1 ZIP code confirmed via EPA Community Water System Service Area Boundaries v3 plus 4 additional ZIPs inferred from SDWIS registry data. The EPA-confirmed set is the most reliable; SDWIS-inferred entries may be narrower than the real deployment area.
Data Sources
This report uses public data from the EPA Safe Drinking Water Information System (SDWIS). View the full compliance record for Doylestown Boro Water Department (PA1090081) on EPA.gov.
Frequently Asked Questions
Is Doylestown Boro Water Department water safe to drink?
Doylestown Boro Water Department has only monitoring/reporting violations, which are procedural in nature. The system meets federal health-based standards.
How many people does Doylestown Boro Water Department serve?
Doylestown Boro Water Department serves approximately 8,700 people across 5 ZIP codes in Pennsylvania.
Where does Doylestown Boro Water Department get its water?
The primary water source is groundwater.
Treatment regime
How this utility classifies its treatment process and what each reported treatment chemical does.
Treatment chemicals and what each one does
Chemical names are reported verbatim by the utility. Purpose categories are ZipCheckup annotations based on standard drinking-water treatment practice.
Treatment classification and chemical list sourced from Doylestown Boro Water Department Consumer Confidence Report.
Treatment intensity is a ZipCheckup-derived classification based on the chemicals and processes the utility reports. Chemicals and contamination sources are taken verbatim from the utility's CCR filing. Routine federal monitoring and contaminant testing shown elsewhere on this page determine whether the water meets safety standards, not the treatment classification.
Federal UCMR5 PFAS Monitoring: Above Current MCL
This water system was tested under the federal EPA Unregulated Contaminant Monitoring Rule (UCMR5). One or more PFAS compounds were measured above the current state-enforceable MCL.
Current MCL reflects the lowest state-enforceable limit (NYS 10 ppt for PFOA/PFOS, effective August 2020). The federal final MCL of 4 ppt for PFOA/PFOS (EPA April 2024 rule) is not enforceable until April 2029. Detections above 4 ppt but below 10 ppt are below current MCL but above the future federal limit.
Source: U.S. EPA UCMR5 (Unregulated Contaminant Monitoring Rule, 5th cycle) — per-system federal sampling, 2023–2025. EPA UCMR5 monitoring program →
PFAS Substances Detected in This System
This water system's Consumer Confidence Report disclosed the following PFAS compounds. Levels are from the utility's most recent reporting cycle.
In April 2024, EPA finalized the first National Primary Drinking Water Regulation for six PFAS. Public water systems have until 2029 to comply. EPA — PFAS regulation overview →
Source: Consumer Confidence Report disclosed by Doylestown Boro Water Department.
ZipCheckup is not affiliated with this water utility. PFAS detection data is sourced from public Consumer Confidence Reports filed by the utility itself.
Lead Service Line Inventory
Service line breakdown reported under the federal Lead and Copper Rule Improvements (LCRI) inventory requirement:
Federal LCRI rule (effective October 2024) requires every public water system to inventory its service lines and complete lead-line replacement within 10 years.
Source: EPA SDWIS Federal Service Line Inventory (Phase 2) · Submitted 2026
ZipCheckup is not affiliated with the utility or state agency. Inventory figures render verbatim from the public LCRI submission cited above; ZipCheckup does not perform inspections or replacements.
Frequently Asked Questions
What You Can Do
Test your water
Home test kits can detect lead, bacteria, and other contaminants at your tap. Find the right filter →
Check your specific ZIP code
Water quality can vary within a system. View nearest ZIP report →
Contact your utility
Doylestown Boro Water Department (EPA ID: PA1090081) — request the latest Consumer Confidence Report or ask about specific contaminants.