Rio Water Supply Corporation
EPA ID: TX2140016 ยท 6,939 people served ยท 1 ZIP code
ZipCheckup's reading of EPA SDWIS for Rio Water Supply Corporation (TX2140016): 4 unresolved EPA violations on record. Compliance tracking for Rio Water Supply Corporation shows 4 pending violations logged in the EPA system - the supplier delivers water to approximately 6,939 residents while those findings remain open.
Data: EPA SDWIS
Service Area Map
Coverage area for Rio Water Supply Corporation Source: EPA SDWIS service area boundaries.
Service area boundary
Service Area Demographics
The Rio Water Supply Corporation serves a community with a median household income of $41,452 and an estimated 44,883 residents across its service area.
Environmental Justice Note: 100% of the population in this service area is classified as disadvantaged under EPA's EJScreen criteria. Communities with higher disadvantaged populations often face disproportionate environmental and health burdens, including aging water infrastructure and limited resources for remediation.
๐ Where Does Your Water Come From?
Rio Water Supply Corporation's water is drawn from rivers, lakes, or reservoirs. Surface water sources are more exposed to agricultural runoff, stormwater, and upstream discharges, but they typically receive more intensive treatment before reaching your tap.
Infrastructure Risk
Detected Contaminants
How Rio Water Supply Corporation compares to EPA limits
What This Means For You
Lead at 1 mg/L (action level) exceeds the EPA maximum of 0.015 mg/L (action level). Brain damage in children, kidney & blood pressure in adults. Consider reverse osmosis filtration.
Haloacetic Acids (HAA5) at 1 mg/L exceeds the EPA maximum of 0.06 mg/L. Cancer risk; reproductive & developmental effects. Consider granular activated carbon (GAC) filtration.
Total Trihalomethanes (TTHM) at 1 mg/L exceeds the EPA maximum of 0.08 mg/L. Bladder & rectal cancer risk; reproductive concerns. Consider granular activated carbon (GAC) filtration.
Lead and Copper Rule at 4 mg/L exceeds the EPA maximum of mg/L.
Surface Water Treatment Rule at 3 mg/L exceeds the EPA maximum of mg/L.
PFAS Detected in Service Area
PFAS ("forever chemicals") have been detected in water serving this system's area. 3 detections recorded.
Lead was detected in this water system. reverse osmosis filtration can reduce exposure.
Find a certified water filter โComparable Water Systems
Similar-sized systems in Texas
Estimated Remediation Costs
Average estimated costs across ZIP codes served by this system
Based on national averages for common remediation projects. Actual costs vary by property. Only issues flagged by EPA, FEMA, or state data for each ZIP code are included.
System Overview
Rio Water Supply Corporation (EPA ID: TX2140016) is a community water system in Texas that serves approximately 6,939 people from surface water sources.
This system serves ZIP code 78582 in Rio Grande City.
Violation History
Status breakdown for accepted records with record years 2021-2026: 10 resolved, 0 archived, 0 addressed, and 4 unaddressed. Under this source contract, current noncompliance is the sum of addressed and unaddressed records. Archived and resolved records are excluded from current noncompliance.
Recent Violations
| Date | Contaminant | Type | Status |
|---|---|---|---|
| November 1, 2025 | Fecal Coliform | Non-health-based | Resolved |
| October 17, 2024 | Stage 2 DBP Rule | Health-based | Resolved |
| October 17, 2024 | Stage 2 DBP Rule | Non-health-based | Resolved |
| July 1, 2023 | Surface Water Treatment Rule | Non-health-based | Resolved |
| July 1, 2022 | Surface Water Treatment Rule | Non-health-based | Resolved |
| December 30, 2021 | Stage 1 DBP Rule | Non-health-based | Resolved |
| December 23, 2021 | Lead and Copper Rule | Non-health-based | Unaddressed (current) |
| November 1, 2021 | Lead and Copper Rule | Non-health-based | Unaddressed (current) |
| October 1, 2021 | Lead and Copper Rule | Non-health-based | Unaddressed (current) |
| October 1, 2021 | Haloacetic Acids (HAA5) | Non-health-based | Resolved |
| October 1, 2021 | Total Trihalomethanes (TTHM) | Non-health-based | Resolved |
| October 1, 2021 | Lead | Non-health-based | Resolved |
| September 1, 2021 | Lead and Copper Rule | Non-health-based | Unaddressed (current) |
| July 1, 2021 | Surface Water Treatment Rule | Non-health-based | Resolved |
Contaminants Detected
The following contaminants have been flagged in EPA records for this water system:
| Contaminant | Category | Violations | Health-Based |
|---|---|---|---|
| Lead and Copper Rule | Treatment Failure | 4 | No |
| Surface Water Treatment Rule | Treatment Failure | 3 | No |
| Stage 2 DBP Rule | Treatment Failure | 2 | Yes |
| Lead | Inorganic | 1 | No |
| Total Trihalomethanes (TTHM) | Disinfection Byproducts | 1 | No |
| Haloacetic Acids (HAA5) | Disinfection Byproducts | 1 | No |
| Stage 1 DBP Rule | Treatment Failure | 1 | No |
| Fecal Coliform | Microbiological | 1 | No |
Lead & Copper
EPA Lead and Copper Rule evidence attributed directly to this water system:
| Lead Level | Exceeds Action Level | Sample Date |
|---|---|---|
| 0 mg/L | No | N/A |
No copper action-level exceedance record appears for this PWSID in the accepted LCR snapshot. This does not establish a clean copper measurement.
Need help with your water quality?
Typical cost: Water test: typically $20โ$50 (DIY kit) ยท Professional inspection: $150โ$400
Find the Right Water FilterFree tip: Let cold water run for 2 minutes before drinking โ this helps flush lead from your pipes.
ZIP Codes Served
Coverage: Service area ZIP codes sourced from EPA Community Water System Service Area Boundaries v3 (March 2026 release). These ZIPs reflect the actual deployment footprint recorded by TX or modeled from parcel and building-footprint data.
- 78582 - Rio Grande City
Data Sources
This report uses public data from the EPA Safe Drinking Water Information System (SDWIS). View the full compliance record for Rio Water Supply Corporation (TX2140016) on EPA.gov.
Frequently Asked Questions
Is Rio Water Supply Corporation water safe to drink?
The accepted 2026Q2 ECHO snapshot shows 4 current noncompliance records and zero current records classified as health-based. That classification is not a property-specific water test or safety guarantee.
How many people does Rio Water Supply Corporation serve?
Rio Water Supply Corporation serves approximately 6,939 people across 1 ZIP code in Texas.
Where does Rio Water Supply Corporation get its water?
The primary water source is surface water.
Federal UCMR5 PFAS Monitoring: Detected
This water system was tested under the federal EPA Unregulated Contaminant Monitoring Rule (UCMR5). PFAS compounds were detected below the current state-enforceable MCL.
Current MCL reflects the lowest state-enforceable limit (NYS 10 ppt for PFOA/PFOS, effective August 2020). The federal final MCL of 4 ppt for PFOA/PFOS (EPA April 2024 rule) is not enforceable until April 2029. Detections above 4 ppt but below 10 ppt are below current MCL but above the future federal limit.
Source: U.S. EPA UCMR5 (Unregulated Contaminant Monitoring Rule, 5th cycle) โ per-system federal sampling, 2023โ2025. EPA UCMR5 monitoring program โ
How Water Systems Appear in Rankings
Water systems are evaluated by violation history, contaminant detections, and service population. Larger systems with more service connections appear in more rankings.
Frequently Asked Questions
How to cite this page
ZipCheckup. (n.d.). Rio Water Supply Corporation (TX): 1 Health Violation. https://zipcheckup.com/water-system/tx2140016/
@misc{zipcheckup-water-system-tx2140016,
author = {{ZipCheckup}},
title = {{Rio Water Supply Corporation (TX): 1 Health Violation}},
year = {n.d.},
url = {https://zipcheckup.com/water-system/tx2140016/}
}
What You Can Do
Test your water
Home test kits can detect lead, bacteria, and other contaminants at your tap. Find the right filter โ
Check your specific ZIP code
Water quality can vary within a system. View nearest ZIP report โ
Contact your utility
Rio Water Supply Corporation (EPA ID: TX2140016) - request the latest Consumer Confidence Report or ask about specific contaminants.